Product Center

  • SK-5000A/SK-5000B Non Contact Tonometer
  • SK-5000A/SK-5000B Non Contact Tonometer
Name:SK-5000A/SK-5000B Non Contact Tonometer

Product Description

SK-5000A/SK-5000B Non Contact Tonometer


Features:

Ø Touch lightly, 3D automatic intraocular pressure measurement for both eyes

Ø Air jet test: after the machine is turned on, check whether the measuring system of the instrument works normally

Ø Safety limit: it can avoid the contact between the air jet mouth and the patient's eyes. When the air jet mouth is too close to the patient's eyes, the buzzer will give an alarm

Ø It can monitor intraocular pressure dynamically 24 hours, and print it on the same report sheet with intraocular pressure data

 

Parameters:

Display

7" 1024 * 600 color touch screen
Support up and down 180 left and right 60 turning

Fixation lamp

1 internal fixation lamp (green LED); 2 external fixation lamps

Measuring head moving range

Up and down stroke: 45mm, left and right stroke: 90mm, front and back stroke: 40mm

Lifting range of lower jaw drag

68mm

Working distance

11mm (calculated from the front of nozzle)

Measurement accuracy

1mmHg (0.133Kpa)

Measuring range

0-60mmhg (0-8kpa} (including free switching between 30 | 60mmhg)

Power Supply

AC100-240V50/60HZ

Ambient temperature

50°

Scope of operation

16mmx10mm

Printer

Built in thermal printer

Data storage

Internal memory card + optional external USB memory

Networking

DICOM3.0

Measurement mode

Fully automatic/automatic/manual

Operating system

Embedded system

Mobile platform

Fully automatic platform I manual platform

Data input and output

Input: USB; output: LAN/ RS232C

Focusing mode

3D full auto focus/manual focus

Jet detection

After power on, check whether the measuring system of the instrument works normally

Safety limit

Support

Intraocular pressure measurement

Each eye was measured three times continuously, and the average value was calculated Normal intraocular pressure range: 1021mmhg (1.33kpa 2.80kpa)

Corneal thickness measurement

Each eye was measured three times continuously, and the average value was calculated Normal corneal thickness: about 550um

Full automatic measurement

Press the measurement button to complete the intraocular pressure test automatically

24-hour dynamic intraocular pressure measurement

It can monitor intraocular pressure dynamically 24 hours, and print it on the same report sheet with intraocular pressure data

Printing

Data can be printed directly after measurement

Storage

10 sets of measurement data can be stored

Data export

Can be exported to PDF or JPG format




Hits: 【Print】